If you’ve been told you “need to get a BAL report” it’s quite understandable you might be wondering what does this involve?

If your area has been desig...

What does a “BAL assessment” actually involve?

August 18, 2017

1/1
Please reload

Featured Posts

What standard applies to buildings in bushfire areas?

September 20, 2017

In addition to regular construction standards, residential buildings* in designated bushfire areas are required to comply with “Australian Standard AS3959 – Construction of buildings in bushfire-prone areas”.

 

The aim is for the building to “provide a measure of protection to the building occupants (until the fire front passes) as well as to the building itself”. The standard is used to determine:

  1. The potential threat level to the building from bushfire-prone vegetation; and

  2. The construction standards that apply for the determined threat level.

The six threat levels (known as Bushfire Attack Levels, or BALs) are based on the potential radiant heat exposure to a building, and AS3959 details the contruction standards relevant to each BAL.

 

BAL-LOW

There is insufficient risk to warrant specific construction requirements.

 

BAL-12.5

Ember attack.

 

BAL-19

Increasing levels of ember attack and burning debris ignited by windborne embers together with increasing heat flux.

 

BAL-29

Increasing levels of ember attack and burning debris ignited by windborne embers together with increasing heat flux.

 

BAL-40

Increasing levels of ember attack and burning debris ignited by windborne embers together with increasing heat flux with the increased likelihood of exposure to flames.

 

BAL-FZ

Direct exposure to flames from fire front in addition to heat flux and ember attack.

 

The Western Australian Building Commission provides resources and information, including answers to a comprehensive range of Frequently Asked Questions, relating to building standards in bushfire areas.

 

While designed to improve safety, it should be noted the “measure of protection” provided by AS3959 is no guarantee that a building will withstand a bushfire. It is also crucial to have ongoing management of the bushfire threat and a clear emergency action plan.

 

* residential buildings include class 1,2 and 3 buildings, and any associated class 10.

 

Jeremy Durston (BPAD36525)

Share on Facebook
Share on Twitter
Please reload

Follow Us
Please reload

Search By Tags
Please reload

Archive
  • Facebook Basic Square
  • Twitter Basic Square
  • Google+ Basic Square
Our Location:

We are based centrally in Perth and we service Metro and Regional areas.

Contact us: 

Jeremy Durston BPAD36525

jeremy@bushfirewest.com.au

ph: 0403328835

© 2017 by Bushfire West.

Proudly created with Wix.com